The global
success of the Elanra therapeutic ionisers has encouraged a
number of companies to manufacture ionisers that do not live up
to expectations. Although these machines have been designed to
look substantial, on examination the electronics and operation,
in our opinion, is well below-par, and in some cases dangerous.
It is a fact
that some of these "so-called" ionisers only produce harmful
Ozone or utilise outdated technology. (See
EPA report)
To be efficient and effective, an ioniser must be manufactured
to the highest standards.
We have endeavoured to show the
internal circuitry of a number of the ionisers currently on the
global market.
|
|
Under controlled conditions, we scientifically measured the
ion output of the ionisers shown below. |
The Actual
negative ion outputs were measured in ions per cubic centimetre.
|
Date of Tests: |
2002 -
2003 |
|
Time For Each Test: |
15
Minutes |
|
Temperature: |
20°C
+/- 1° |
|
Humidity: |
70%
+/- 5% |
|
Background Negative Ions: |
400 per CC
+/- 25% |
|
Background Positive Ions: |
50 per CC
+/- 10% |
Note: The background
negative and/or positive ions in all cases, were added or deducted from
the results shown below.
|

View Larger Image
View Needle
View PCB |
|
Claimed Output |
Actual Output @1M |
Actual Output @2M |
|
1,000,000 |
130,000 |
600 |
-
Ozone Produced:
Minimal - Below
maximum safe level
-
Summary:
No small ions produced. Output at 2m insufficient
even for effective air cleaning function.
-
Circuitry:
Typical voltage multiplier on an average-quality
printed circuit board with average quality
components. Mains Powered
-
Ion Discharge system:
Steel needles
|
|
|

View Larger Image
View Base Unit
View Needle
View PCB |
|
Claimed Output |
Actual Output @1M |
Actual Output @2M |
|
1,000,000 |
300 |
50 |
-
Ozone Produced:
Not detected
-
Summary:
Number of ions produced is below any useful
level. Although it utilises a small fan & air
filter.
-
Circuitry:
Neatly built voltage multiplier circuit &
on-board electric motor. DC Power Supply.
-
Ion Discharge
system:
Steel needles.
|
|
|
|

View Larger Image
View Needle
View PCB |
|
Claimed Output |
Actual Output
@1M |
Actual Output
@2M |
|
Not Quoted |
NIL |
NIL |
-
Ozone Produced:
YES
-
Summary:
No ions produced at all – only harmful
ozone.
-
Circuitry:
Poorly made and in-adequate. 9V Battery & DC
Power Supply.
-
Ion Discharge
system:
Supposed ion-producing needle is merely the
sharpened end of a 2c resistor.
|
|
|
|
|

View Larger Image
View Needle
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
215,000 |
120,000 |
1000 - 2000 |
-
Ozone Produced:
Not detected
-
Summary:
Their claim of Astrid having a variable
output is false and deceptive. The
machine contains no circuitry or any
other mechanism to achieve their claim.
-
Circuitry:
Simple voltage multiplier. Mains
Powered.
-
Ion
Discharge system:
Steel non-replaceable needles.
|
|
|
|
|
|

View Larger Image
View Needle
View PCB |
|
Claimed Output |
Actual Output
@1M |
Actual Output
@2M |
|
Not Quoted |
NIL |
NIL |
-
Ozone Produced:
Not detected
-
Summary:
No ions produced at all. Product made to
capitalise on the gullible and naïve.
(Compare with performance and testimonials
on Elanra Portable model for in-vehicle or
in-transit use).
-
Circuitry:
Poorly designed circuitry of low quality.
12V DC Car Powered
-
Ion Discharge
system:
Standard steel needle in screw-in socket. No
indication of when replacement is required.
(This is an academic comment as the machine
produces nothing.)
|
|
|
|
| |
|

View Larger Image
View Needle
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not Quoted |
130,000 |
24,000 |
-
Ozone Produced:
Not detected
-
Summary:
Well-built but poor quality componentry.
-
Circuitry:
Simple voltage multiplier. DC Power
Supply.
-
Ion
Discharge system:
Non-replaceable strip with stamped
pins. Low quality, subject to
oxidisation.
|
|
|
|
|
|

View Larger Image
View Filament1
View Filament2
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not Quoted |
120,000 |
14,000 -
28,000 |
-
Ozone Produced:
Not detected
-
Summary:
No small ions produced. Unstable output.
Machine suitable only for some limited
air cleaning.
-
Circuitry:
Surface Mounted high voltage multiplier.
Mains Powered.
-
Ion
Discharge system:
Non-replaceable filament,
carbon-impregnated. Easily clogged
making machine ineffective –this is
characteristic of filament type
machines.
|
|
|
|
|
|

View Larger Image
View Needle
View PCB1
View PCB2 |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
3,000,000,000,000 |
90,000 |
20,000 |
-
Ozone Produced:
Not detected
-
Summary:
Machine
suitable for very limited air cleaning.
-
Circuitry:
Two sets of voltage multipliers of
reasonable quality with protective
covering. Mains Powered.
-
Ion
Discharge system:
Steel needles
|
|
|
|
|
|
|
|
Geomed
Breeze Air Energiser |

View Larger Image
View Needle
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
5,000,000 |
|
0% Fan |
150,000
- 200,000 |
|
50% Fan |
280,000
- 300,000 |
|
100% Fan |
280,000
- 300,000 |
|
|
0% Fan |
22,000 |
|
50% Fan |
40,000 -
60,000 |
|
100% Fan |
40,000 -
70,000 |
|
-
Ozone Produced:
Not detected
-
Summary:
The claimed output of 5,000,000 ions per
Cubic Centimetre at 1 metre is false &
deceptive. In Geomed's own test report,
dated 30th October 2002, using their own
Ionometer IM5005 Geomed state that the
average negative ion density at 2 metres
was 42,652 ions per
Cubic Metre.
If this is correct, they are actually
stating that their ioniser is producing
less than
HALF AN ION per Cubic
Centimetre at 2 Metres. This plainly
demonstrates that the Geomed Breeze Air
Energiser has absolutely no ability to
produce small biologically active ions,
as their ion mobility factor is hardly
desrenable.
-
Circuitry:
Appears to be a basic voltage multiplier
as the circuit board was embedded in a
plastic can filled with gel. Mains Powered.
-
Filter System:
A filter
medium is used to clean the air from
large particles. The Fan used appeared
to be of reasonable quality.
-
Ion
Discharge system:
Gold Plated Needles - NON REPLACEABLE
-
Other Comments:
We cannot
see how this Geomed Ioniser warrants its
$1200 US Dollar price tag.
|
|
|
|
|
|

View Larger Image
View Needle
View PCB1
View PCB2 |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not Quoted |
NIL |
NIL |
-
Ozone Produced:
YES
-
Summary:
Does NOT produce negative ions – it is an
ozone generator.
-
Circuitry:
Not Applicable
-
Ion
Discharge system:
Not Applicable
|
|
|
|
|
|

View Larger Image
View Needle1
View Needle2
View PCB1
View PCB2 |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not Quoted |
60,000 |
200 - 600 |
-
Ozone Produced:
Minimal -
Below maximum safe level
-
Summary:
No small ions produced. Actual
performance ineffective. No ion
mobility. Ions produced at 2m
insufficient for effective air cleaning.
-
Circuitry:
Exceptional quality circuit board with
small fan, very well
designed. DC Power Supply.
-
Ion
Discharge system:
Extremely fine filament. We were
surprised that this machine was not more
effective, given the quality of
circuitry and ion emission system.
|
|
|
|
|
|

View Larger Image
View Needle
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not Quoted |
60,000 |
6000 -
10,000 |
-
Ozone Produced:
Minimal -
Below maximum safe level
-
Summary:
Machine suitable for limited air
cleaning.
-
Circuitry:
Very old technology. Mains Powered.
-
Ion
Discharge system:
Non-replaceable needle strip similar to
the Bionaire system with same disadvantages
of no warning when replacement required.
Needle rapidly blunts reducing output.
|
|
|
|
|
|
|
Medion Pulsar
1980's Ioniser |

View Larger Image
View Needle
View PCB |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not
Quoted |
100,000 |
10,000 -
14,000 |
-
Ozone
Produced:
Not detected
-
Summary:
Machine suitable for limited air
cleaning.
-
Circuitry:
Good quality circuit board. Mains
Powered.
-
Ion
Discharge system:
Stainless Steel needles
|
|
|
|
|
|
|

View Larger Image
View Needle
View PCB1
View PCB2 |
|
Claimed
Output |
Actual
Output @1M |
Actual
Output @2M |
|
Not
Quoted |
60,000 |
100 -
1,000 |
-
Ozone
Produced:
YES
-
Summary:
Negative ions & ozone produced
simultaneously. Output at 2m
insufficient for effective air
cleaning. Should be used with care.
-
Circuitry:
Exceptionally
Well designed & constructed with top
quality components. DC Power Supply.
-
Ion
Discharge system:
Stainless Steel needles.
|
|
|
|
|
|
|
| | |